Worcester Bosch Greenstar 8000 F Regular
200
Boiler in heating mode
201
Boiler in hot water mode
202
Boiler in anti-cycle mode
203
Boiler in standby, no heat energy demand
204
Current prim. water temp. higher than set val.
208
Chimney sweep demand
214
Fan shut down during safety time
224
Maximal flue gas thermostat or heat exchanger maximal thermostat has activated
227
No flame signal after ignition
228
Flame signal without flame present
229
Flame failed during burner operation
232
Boiler locked by external switching contact
233
Boiler identification module or device electronics faulty
234
Gas valve electrical fault
235
Conflicting versions of boiler electr. and boiler identification
237
System fault
238
Boiler electronics faulty
242
Boiler electr. system fault
244
System fault boiler electronics / basic controller
245
System fault boiler electronics / basic controller
246
System fault boiler electronics / basic controller
247
System fault boiler electronics / basic controller
248
System fault boiler electronics / basic controller
249
System fault boiler electronics / basic controller
250
System fault boiler electronics / basic controller
251
System fault boiler electronics / basic controller
252
System fault boiler electronics / basic controller
253
System fault boiler electronics / basic controller
254
System fault boiler electronics / basic controller
257
System fault boiler electronics / basic controller
258
System fault boiler electronics / basic controller
259
System fault boiler electronics / basic controller
262
System fault boiler electronics / basic controller
263
System fault boiler electronics / basic controller
265
Heat demand lower than energy supplied
268
Relay test was activated
269
Flame monitoring
273
Operation of burner and fan interrupted
281
Pump stuck or running in air
283
Burner starting
284
Opening air/gas ratio control valve/oil solenoid valves
306
Flame signal after closing the fuel supply
357
Ventilation program
358
Anti-seizing functn. active
360
System fault boiler electronics / basic controller
362
Boiler identification module or boiler electronics faulty
363
System fault boiler electronics / basic controller
604
System fault burner control unit
815
Low loss header temp. sensor faulty
1010
No communication via EMS BUS connection
1013
Max. combustion point reached
1018
Maintenance interval expired
1019
Incorrect pump type detected
1022
Cylinder temp. sensor faulty or contact problems
1023
Maximum run time including standby time reached
1025
Return temp. sensor is faulty
1037
Outside temp. sensor faulty - heating backup operation active
1068
Outside temp. sensor or lambda probe faulty.
1070
Maintenance is due on <dd.mm.yyyy> please call your service engineer
1071
Maintenance is now due please call your service engineer
1072
Maintenance is overdue please call your service engineer
1075
Heat exchanger temp sensor short circuit
1076
Heat exchanger temp sensor disconnected
2085
Internal fault
2908
System fault boiler electronics / basic controller
2910
Fault in flue system
2914
Boiler electr. system fault
2915
Boiler electr. system fault
2916
Boiler electr. system fault
2920
Fault in flame monitoring
2923
Boiler electr. system fault
2924
Boiler electr. system fault
2925
Boiler electr. system fault
2926
Boiler electr. system fault
2927
Flame failed during burner operation
2928
Internal fault
2931
System fault boiler electronics / basic controller
2940
System fault burner control unit
2946
Incorrect code plug detected
2948
No flame signal with low output
2949
No flame signal with high output
2950
No flame signal following starting procedure
2951
Loss of flame too many times
2952
Internal fault when testing the ionisation signal
2955
Boiler does not support the parameters set for the hydraulic configuration
2956
Hydraulic configuration at the boiler activated
2957
Boiler electr. system fault
2961
No fan signal available
2962
No fan signal available
2963
The heat exchanger sensor or both supply and heat exchanger sensors are defect
2965
Flow temperature too high
2966
Flow temperature rise in heat exchanger too rapid
2972
Mains voltage too low
2980
Locking fault: To unlock Hold up and down arrow keys pressed simultaneously for 3 s. For more information see operating instr. (Boiler locked. Contact a qualified heating engineer)
2981
Locking fault: To unlock Hold up and down arrow keys pressed simultaneously for 3 s. For more information see operating instr. (Boiler locked. Contact a qualified heating engineer)