Greenstar 1000 Combi
Worcester Bosch Greenstar 1000 Combi
200
Boiler in heating mode
201
Boiler in hot water mode
202
Boiler in anti-cycle mode
203
Boiler in standby, no heat energy demand
204
Current primary water temperature higher than set val.
208
Chimney sweep demand
213
Temp difference between supply and return exceeding limit
214
Fan shut down during safety time
219
Supply or return water too hot
222
Interruption of the NTC cabling
223
Interruption of the NTC cabling
224
Safety temp. limiter has tripped
227
No flame signal after ignition
228
Flame signal without flame present
229
Flame failed during burner operation
232
Boiler locked by external switching contact
233
Boiler identification module or device electronics faulty
234
Gas valve electrical fault
235
Conflicting versions of boiler electr. and boiler identification
237
System fault
238
Boiler electronics faulty
240
Interruption of the NTC cabling
241
Interruption of the NTC cabling
245
State out of range
249
Internal software error
250
Default software error
251
Flash test error
252
Stack overflow
253
RAM test error
254
Eeprom test error
258
Internal watchdog error
259
AD reference error
262
Internal OS error
263
Program sequence error
265
Heat demand lower than energy supplied
268
Relay test was activated
269
Flame monitoring
270
Starting up boiler
273
Operation of burner and fan interrupted
275
Boiler electronics in test mode
278
Sensor test failed: DHW mode and heating mode do not function
283
Burner starting
284
Opening air/gas ratio control valve/oil solenoid valves
285
Return temperature is too hot
305
Heat exchanger in hot water anti-cycle mode
306
Flame signal after closing the fuel supply
341
Temperature rise at heat exchanger too rapid
347
Return temp exceeds flow temp for over 20 sec
351
Flow temperature sensor interrupted
353
Test non-volatile lockout
357
Ventilation program
358
Anti-seizing functn. active
360
Incomparable code plug
362
Boiler identification module or boiler electronics faulty
363
Ionisation current did not drop during ionisation test
364
Solenoid valve ev2 leaking.
365
Solenoid valve ev1 leaking.
568
Water Pressure Sensor not connected or defect
578
NTC is damaged
522
NTC Drift Test is running
604
System fault burner control unit
1010
No BUS communication
1013
Max. combustion point reached
1018
Maintenance interval expired
1019
Incorrect pump type detected
1021
Cylinder charging or hot water temperature sensor faulty
1023
Maximum run time including standby time reached
1025
Return temp. sensor is faulty
1068
Outside temp. sensor or lambda probe faulty
1073
Short circuit of the flow temperature sensor
1074
No signal from flow temperature sensor
2085
Internal fault
2207
Low level/ no PWM signal from the calculation pump
2908
System fault boiler electronics/basic controller
2910
Fault in flue system
2915
The fan keeps running after the post purge
2916
Gas valve was detected to be open during post purge
2920
Fault in flame monitoring
2923
Unexpected feedback from the modulating/ current controlled gas valve
2924
No feedback from the gas valve
2925
Too low feedback from the modulating gas valve
2926
Too high feedback from the modulating/ current controlled gas valve
2927
Flame failed during operation
2928
Internal error
2930
System fault heat exchanger electronics / basic controller
2931
Illegal instruction executed by microcontroller
2940
Low voltage
2946
Incorrect code plug detected
2948
No flame signal with low output
2949
No flame signal with high output
2950
No flame signal following starting procedure
2951
Loss of flame too many times
2952
Internal fault when testing ionisation signal
2955
Heat exchanger does not support the parameters set for the hydraulic configuration
2956
Hydraulic configuration at the heat exchanger activated
2957
Internal control error
2958
System fault, appliance electronics
2959
System fault, appliance electronics
2960
System fault, appliance electronics
2961
No fan signal available
2962
Fan not running
2963
Signal from flow and heat exchanger temperature sensor outside the permissible range
2964
Flow rate in heat exchanger too low
2965
Flow temperature too high
2966
Flow temperature rise in heat exchanger too rapid
2972
Mains voltage too low
2973
System fault boiler electronics / basic controller
2974
Internal fault
2980
Super lock out fault: The appliance has been reset 6 times within 15 minutes. (Boiler locked. Contact a qualified heating engineer)
2981
Super lock out fault: The appliance has been reset 6 times within 15 minutes. (Boiler locked. Contact a qualified heating engineer)
Combustion noises too loud; rumbling noises
Faults that are not displayed
Flow noises
Faults that are not displayed
Heat-up takes too long
Faults that are not displayed
Flue gas values incorrect; CO content too high
Faults that are not displayed
Delayed ignition, poor ignition
Faults that are not displayed
Condensate in air box
Faults that are not displayed
No hot water.
Faults that are not displayed
DHW volume is not reached
Faults that are not displayed
No function, the display remains dark
Faults that are not displayed