2925
Too low feedback from the modulating gas valve
Worcester Bosch Greenstar 1000 Combi
Remedy
▶ Check the voltage to the gas valve.
▶ Check the resistance of the gas valve coils.
▶ Check the continuity of harness and replace if required.