Super lock out fault: The appliance has been reset 6 times within 15 minutes. (Boiler locked. Contact a qualified heating engineer)

Worcester Bosch Greenstar 1000 Combi

Category
V
Remedy
▶ After power cycle 2980 will switch to 2981.
▶ Diagnose and remedy the locking fault. Check the complete system, including sensors and harnesses.
▶ When remedied and system checked, turn the boiler power off and on again.
▶ Fault condition 2980/2981 will appear, the boiler is still in super lock-out.
▶ Press ▲ and ▼ simultaneously for 3 seconds.
▶ Immediately after 22 seconds have elapsed, perform an additional reset by pressing ▲ and ▼ simultaneously for 3 seconds.
▶ Super lock-out is remedied, boiler returns to normal operating condition.
▶ Fault history is now available, double check the last 10 faults to confirm the fault has been remedied.