BoilerTool
Home / Greenstar 8000 F Combi / 2950
2950

No flame signal following starting procedure

Worcester Bosch Greenstar 8000 F Combi

Category
B
Remedy
Burner starts automatically after purging.
Check gas pressure whilst burning at full load.
Check the CO2 and O2 settings, adjust if necessary.
Check Burner and heat exchanger gaskets.
This code also applies to: