Boiler electr. system fault
Worcester Bosch Greenstar 4000 System
Category
V
Remedy
Gas valve was detected as open during post-purge.
▶ Carry out a gas tightness test on the gas valve and replace if required.
▶ Check the voltage to gas valve.
▶ The gas valve or the PCB may be defective
This code also applies to:
Condens 7000 WP
Greenstar 1000 Combi
Greenstar 2000 Combi
Greenstar 4000 Combi
Greenstar 8000 F Combi
Greenstar 8000 F Regular
Greenstar 8000+ Style
Greenstar 8000+
Source:
Manufacturer manual (PDF)