Delayed ignition, poor ignition.
Faults that are not displayed
Worcester Bosch Greenstar 4000 Combi
Remedy
▶ Check the ignition transformer function for misfiring in the Function check menu Ignition test, replace if required.
▶ Check the gas type.
▶ Check the gas supply pressure.
▶ Check the power supply.
▶ Check the electrodes with cable; replace if required.
▶ Check the flue system; clean or repair if required.
▶ Check the gas/air ratio.
▶ For natural gas: check the external gas flow monitor, replace if required.
▶ Check the burner, replace if required.
▶ Check the gas valve; replace if required.
This code also applies to: