Vaillant ecoTEC Plus Combi
F.000
The signal for the flow temperature sensor has been interrupted.
F.001
The signal for the return temperature sensor has been interrupted.
F.002
The signal for the domestic hot water connection temperature sensor has been interrupted.
F.003
The signal for the cylinder temperature sensor has been interrupted.
F.010
The flow temperature sensor has short-circuited.
F.011
The return temperature sensor has short-circuited.
F.012
The domestic hot water connection temperature sensor has short-circuited.
F.013
The cylinder temperature sensor has short-circuited.
F.020
The safety cut-out (SCO) interrupts the gas valve control. The gas valve was closed because the temperature of the flow or return temperature sensor has exceeded the maximum limit.
F.022
No/insufficient water in the product or the water pressure is too low.
F.023
The temperature spread between the flow/return is too great.
F.024
The temperature increases too quickly.
F.025
The flue gas temperature is too high.
F.027
A flame signal has been detected while the burner is off.
F.028
The flame signal was not detected during the ignition phase.
F.029
The ignition following a flame loss during operation was unsuccessful.
F.032
The fan speed is outside of the tolerance.
F.035
The air/flue pipe is blocked.
F.040
The air ratio is too low.
F.042
The coding resistor (in the wiring harness) or the gas group resistor (on the PCB, if available) is invalid.
F.044
The ionisation signal for the control electrode is too low. The drift adaptation has failed.
F.047
The signal for the domestic hot water temperature sensor at the output for the internal cylinder is implausible.
F.049
The eBUS has short-circuited or two active eBUS sources have inverted polarity.
F.057
The combustion regulation has failed and the associated limp home mode has failed.
F.061
The ASIC or μControl does not run in the defined times.
F.062
The flame switch-off was detected after a delay.
F.063
EEPROM reports faults during the read/write test.
F.064
The sensor signal could not be converted correctly.
F.065
The permissible operating temperature range for an electronic component has been exceeded.
F.067
The flame monitor is defective.
F.068
The flame monitor reports an unstable signal.
F.070
The Device Specific Number (DSN) is incorrect, missing or does not match the coding resistor.
F.071
Flow temperature sensor returns implausible values.
F.072
The temperature spread between the flow and return temperature sensor is invalid.
F.074
The signal for the water pressure sensor has been interrupted.
F.075
The pressure change is too low when the heating pump is started up.
F.076
The overheating protection for the primary heat exchanger is active.
F.077
A condensate pump or an external flue non-return flap is blocking the burner operation.
F.078
The control centre is not supported by the unit.
F.080
The cold water inlet temperature sensor in the internal cylinder is defective.
F.081
Cylinder charging has failed.
F.083
When the burner starts, no temperature increase is registered at the flow or return temperature sensor or the temperature increase here is too slow.
F.084
The temperature difference between the flow and return temperature sensors returns implausible values.
F.085
The NTC sensors are installed incorrectly.
F.087
The ignition transformer is not connected to the PCB.
F.088
The electrical connection to the gas valve has been interrupted.
F.089
The installed heating pump does not match the unit type.
F.090
Communication with the internal cylinder has been interrupted.
F.092
The gas-type conversion was not completed correctly.
F.095
The gas valve stepper motor has reached the minimum permissible step number.
F.096
The gas valve stepper motor has reached the maximum permissible step number.
F.097
The self-test of the main PCB has failed.
F.105
When replacing the gas valve assembly or replacing the PCB and the display at the same time, the gas valve assembly offset must be set according to the current gas valve assembly.
F.110
No successful ignition could be detected with the enriched gas-air mixture.
F.194
The power supply unit for the PCB is defective.
F.195
The unit has detected significant undervoltage in the power supply.
F.196
The unit has detected significant overvoltage in the power supply.
F.228
The unit was in limp home mode. In this status, ignition was unsuccessful during the start phase.
F.229
The unit was in limp home mode. In this status, ignition was unsuccessful following a flame loss.
F.235
The air/flue pipe is blocked during initial start-up.
F.281
The flame has failed during the stabilisation period.
F.291
The flame has failed during the stabilisation period following flame loss during operation.
F.317
The signal for the volume flow sensor in the domestic hot water circuit is implausible.
F.318
The 3-port motorised valve does not move.
F.320
The heating pump is blocked. The unlocking function was not successful.
F.321
The pump electronics are defective.
F.322
The heating pump has overheated. The temperature could not be lowered by the limp home mode.
F.323
The heating pump is dry running.
F.324
The electrical connection to the pump has been interrupted.
F.325
The heating pump has a fault.
F.326
The hydraulic sensor and actuator test has detected at least two hydraulic components that are not working.
F.327
The minimum heating volume flow is limited due to there being no domestic hot water circuit connected.
F.330
The pump is not responding to commands during the hydraulic test.
F.334
The configuration of the flue system was not completed.
F.336
The unit is not permitted in this configuration.
F.337
The multiple-flue configuration conversion set is not suitable for the heat cell.
F.338
Incorrect multiple-flue configuration setting
F.342
The air-mass flow is not within the permitted limits.
F.343
The signal for the air-mass flow sensor is not plausible.
F.344
The control electrode can no longer be used.
F.347
Condensate has been detected in the combustion chamber. The burner operation is interrupted.
F.363
The display's EEPROM reports errors during the read/write test.
F.707
No communication is possible between the display and the PCB.
F.905
Communication interface switched off